CD2

Ud. se encuentra en la vista general para el artículo: CD2
Seleccione una variante del artículo en la tabla de la vista general más abajo.

Descripción:
Solid, low-cost FRL service unit made of aluminium equipped with
pressure gauge.

Media: compressed air or non-corrosive gases

Supply_pressure:
max. 16 bar for metal bowl with sight glass,
max. 30 bar for metal bowl without sight glass

Adjustment:
by plastic knob with snap-lock up to G1/2
by hexagon head screw from G3/4 up to G11/2 on (CD.-1A.)
by T-handle from G1½ (CD.-12.) up to G2 on

Relieving_function: relieving, optionally non-relieving
Gauge_port: G1/4 or G1⁄8 at CD.-01/-02, on both sides of the body,
one screw plug supplied
Filter_element: 50 μm, optionally 5 μm or 50 μm,
made of propylene
Bowl: metal version with or without sight glass
Drainage:
semiautomatic drain as standard, optionally automatic (max. 16 bar)
or manual drain for max. 30 bar

Temperature_range:
-10 °C to 50 °C / 14 °F to 122 °F metal bowl with sight glass,
for G1∕8 to G1/2
-20 °C to 60 °C / -4 °F to 140 °F metal bowl with sight glass,
for G3/4 to G2
-30 °C to 80 °C / -22 °F to 176 °F metal bowl without sight glass,
for all sizes

Ocultar descripción del producto